REVISION HISTORY:

Rev 2.0.47 7-10-2024

  • Corrected issue with the IQ355 Motion and over capacity status character.
  • VRS - Added the IOR/IOW commands for serial reading the DIO inputs and setting the DIO outputs.
  • Corrected issue with print tab menu issue with TMP prompts.

Rev 2.0.46 04-05-2022

  • Corrected issue with zeroing in a converted unit with a DLC scale that would change the base unit’s deadload incorrectly.
  • Fixed calibration counters not incrementing properly with DLC builds.
  • Cleaned up DLC diagnostic menu.
  • Added Instance-based backdoor password. Contact Technical Support: 1-866-254-8261 or E-mail: tech@cardet.com for instructions.

Rev 2.0.40 03-04-2021

  • Corrected an issue with local/remote only sending Scale One to remote indicator.
  • Added a program check to stop sending the set calibration deadload command during smart calibration.
  • Corrected an issue that would write out the working deadload before calculating a new deadload when zeroing.
  • Corrected an issue that caused commands to echo back characters to a serial port.

Rev 2.0.39 12-18-2020

  • Added byte order menu for 2XX-Profinet card.
  • Corrected an issue with 2XX-Profinet byte order on keyboard tare commands returned value.
  • Corrected setup menu prompt errors. Any menu with a prompt longer than 32 bytes COULD corrupt other strings and cause the prompting to display incorrect content. We increased the array from 32 to 60 bytes long.
  • Added some version checking with DLC cards so the 225 does not send newer commands to older cards.

Rev 2.0.36 10/15/2020

  • Soft keys were not resetting when leaving menus. With this update, all soft keys are set to none when the “INIT SOFT KEYS” routine is called.
  • Corrected an issue that would cause a print to happen twice.
  • 225D International had an issue with sending too many commands to the display processor depending on optimization levels and physical environment. This has been corrected by increasing the delay to 250ms between display status query at startup.

Rev 2.0.35 9/25/2020

  • Corrected an issue with filtering during dual weigh range operation. The filtering will now reset when going between ranges to prevent the weight from spiking.

Rev 2.0.34 6/22/2020

  • Corrected an issue with the SB600 format for the traffic light and an issue with zero fillings on the SB600 when there is a decimal place.

Rev 2.0.33 6/18/2020

  • This update moved the password prompting to allow any user access to the audit counters without entering a Setup/Review menu password. This only affects the audit counters and will still prompt for and require entering a password (if one is set) when accessing any other menu.

Rev 2.0.32 5/4/2020

  • Removed the prompt for a 777/778/788 remote when configuring a 225-VRS to avoid erroneously selecting it and causing troubleshooting delays.
  • Added support for a new SB600 output format with multiscale display functionality and added a new scale option, Scale (6 (multi)) in the serial menu to output multiple scales on one SB600. This allows four scales to be displayed on the same remote display. NOTE: This new SB600 format is different than the format released in the previous firmware version, Rev 2.0.31 1/15/2020.

Rev 2.0.31 1/15/2020

  • Added the SB600 as a serial output type. This output type adds ~18 bytes at the end of an SB500 style weight string and is still completed by a carriage return.
  • Added a bypass to the span adjust minimum weight requirement. It now will display a percentage of weight for span adjust.

Rev 2.0.30 12/02/2019

  • Moved ID storage preset soft key to shift soft key menu due to interfering with shift soft key Diagnostic and soft key send gross.
  • Added menus to the 2XX-IP menu so that when Toledo output was selected they can choose between the four possible formats.
  • Fixed units key giving incorrect conversion. It was always passing lbs. as the starting unit and now passes the current unit.
  • Changed default byte order for 2XX-EIP option cards from 4321 to 1234.
  • Fixed Send Gross softkey when using SB500 manual mode. Both softkeys can now be use in Normal and ID Storage modes.
  • Added code to default Send Gross port to COM0 (0).
  • This is the initial release of the 225-INTL-DLC version.