This software is required in order to use the 225DLC Digital Load Cell Controller with the 2XX-SNAP for serial communications to a remote display or other serial device.
REVISION HISTORY:
Rev 2.0.47 7-10-2024
• Corrected issue with the IQ355 Motion and over capacity status character.
• VRS - Added the IOR/IOW commands for serial reading the DIO inputs and setting the DIO outputs.
• Corrected issue with print tab menu issue with TMP prompts.
Rev 2.0.46 04-05-2022
• Corrected issue with zeroing in a converted unit with a DLC scale that would change the base unit’s deadload incorrectly.
• Fixed calibration counters not incrementing properly with DLC builds.
• Cleaned up DLC diagnostic menu.
• Added Instance-based backdoor password. Contact Technical Support: 1-866-254-8261 or E-mail: tech@cardet.com for instructions.
Rev 2.0.30 12/02/2019
(This is the initial release of the 225-INTL-DLC-SNAP-serial version.)
• Moved ID storage preset soft key to shift soft key menu due to interfering with shift soft key Diagnostic and soft key send gross.
• Added menus to the 2XX-IP menu so that when Toledo output was selected they can choose between the four possible formats.
• Fixed units key giving incorrect conversion. It was always passing lbs. as the starting unit and now passes the current unit.
• Changed default byte order for 2XX-EIP option cards from 4321 to 1234.
• Fixed Send Gross softkey when using SB500 manual mode. Both softkeys can now be use in Normal and ID Storage modes.
• Added code to default Send Gross port to COM0 (0).
Rev 2.0.26 04/08/2019
• Added two diagnostic screens related to the DLC operation. One screen gives cell power supply voltages and the other gives a count for different groups of communication errors. This will allow scale installers and technicians to be able to troubleshoot issues more accurately.
Rev 2.0.25 03/01/2019
• Added a root password. Note that the root password default is “disabled”.
• Corrected software issues causing the DAC card voltage/current to be inconsistent when the UNITS key is pressed. This was caused by using a DAC max value in the primary unit instead of finding the DAC max value of the secondary unit. The DAC max of the secondary unit is now implemented and is used when the UNITS key is pressed.
• Also corrected zeroing the scale while using the secondary unit.
• For 225D added SETUP MENU #3 option “7. DLC SNAP COMM” to enable/disable wireless scale communications using DLC iSite serial port connected to Snap comm module. Note that the ID of the Synapse module in Snap media box attached to the scale must be entered.
• Added DLC check for updateable digital load cells. If calibration seal allows calibration will prompt “Update?”. (Must have updated DLC 1.0.7 with SmartCell image flashed.)
Rev 2.0.24
• DLC: Added capability to communicate with up to 32 digital load cells.
Rev 2.0.22
• Added ability to print GROSS weight with the push of a soft button labeled SEND GRS.
Rev 2.0.19
• DLC: Added Function for Cell Diagnostics to show “Cell Communication Error Counts” and “Weight Error Counts” screen.
• DLC: When exiting Cell Diagnostics, indicator prompts to “Clear Error Counters?”.
AVR USB Update 225 Main Software Instructions
(AVR-ISP with USB Cable)
For instructions on how to flash the 225 main PC board software, please select Manuals, and then download this PDF:
AVRUSB Update 225 Main Software